Giáo trình Tiếng Anh chuyên ngành - Điện công nghiệp

TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Unit 1: ELECTRICAL MATERIALS  
A. Conducting Materials  
Conducting materials are classified as low resistivity materials and high resistivity materials.  
Low resistivity materials: The conducting materials having resistivity between 10-8 to 10-  
6 ohm-m come under this category and are used in transmission and distribution  
lines, transformers and motor windings such as copper, aluminium, steel, …  
aluminium  
steel  
Copper  
Properties:  
a) Low temperature coefficient: For minimum variations in voltage drop and power loss  
with the change in temperature, these materials should have low temperature coefficient.  
b) Sufficient mechanical strength: These materials must withstand the mechanical stresses  
developed during its use for particular applications.  
c) Ductility: The material to be used for conductors must be ductile so that it can be drawn  
and moulded into different sizes and shapes.  
d) Solderability: The conducting materials are required to be joined and the joint must have  
minimum contact resistance. These materials must have a good solderability.  
e) Resistance to corrosion: The material should have a high resistance to corrosion so that it  
should not be corroded when used in different environmental conditions.  
High resistivity materials: The conducting materials having resistivity between 10-6 to 10-3  
ohm-m come under this category and are used for making resistance elements for  
heating devices, precision instruments, rheostats etc such as manganin, nichrome, mercury,  
platinum, carbon and tungsten, …  
mercury  
manganin  
Properties:  
nichrome  
a) Low temperature coefficient: For minimum variations in voltage drop and power loss  
with the change in temperature, these materials should have low temperature coefficient.  
b) High melting point: These materials, which are used as heating elements should have  
high melting point.  
1
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
c) Ductility: The material to be used for conductors must be ductile so that it can be drawn  
and moulded into different sizes and shapes.  
d) Oxidation resistance: The material should have a high oxidation resistance so that it  
should get oxidised when used in different environmental conditions.  
e) High mechanical strength: These materials must withstand the mechanical stresses developed  
during its use for particular applications.  
B. Semiconducting Materials  
These are the materials, which possess the electrical resistivity in between that of  
conductors and insulators. They are used for the manufacture of diodes and  
transistors. Also the number of valence electrons is equal to four. There is a small forbidden  
energy gap of about 1eV between the conduction and the valence band. Examples:  
germanium, silicon, selenium, etc.  
silicon  
germanium  
Properties:  
Substances like carbon, silicon, germanium whose electrical conductivity lies in  
between the conductors and insulators are known as semiconductors. The valence  
band of these substances is almost filled, but the conduction band is almost empty.  
The forbidden energy gap between valence and conduction band is very small (1ev).  
Therefore comparatively a smaller electric field is required to push the valence  
electrons to the conduction band. This is the reason, why such materials under  
ordinary conditions do not conduct current and behaves as an insulator. Even at room  
temperature, when some heat energy is imparted to the valence electrons, a few of them  
cross over to the conduction band imparting minor conductivity to the semiconductors. As  
the temperature is increased, more valence electrons cross over to the conduction band and  
the conductivity of the material increases. Thus these materials have negative  
temperature co-efficient of resistance.  
C. Insulating Materials  
These are the materials, which do not allow the current to pass through them  
without any appreciable loss. They have very high electrical resistance and are also available  
in a large variety to cover different applications. Some of the specific insulating materials  
are used for the purpose of storing of an electrical energy and are called dielectric materials  
such as mica, ceramic, paper etc. These materials are used as a dielectric in capacitors. Also  
the number of valence electrons is more than four. The energy gap between valence  
2
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
and conduction band is very large (more than 5-6 eV). Examples: Mica, rubber, ceramics,  
glass, diamond etc.  
ceramics  
glass  
mica  
D. Plastic materials  
Plastic materials can be classified into thermoplastic and thermosetting plastics.  
Thermoplastic materials:  
The properties of these plastic materials do not change considerably if they are  
melted and then cooled and solidify. They can be repeatedly melted or dissolved in various  
solvents. They are more elastic, less brittle and do not lose elasticity when subjected to  
prolonged heating. They are less apt to age thermally. They can be remoulded again  
and again in any shape after heating. Many of them possess extraordinary high insulating  
properties and are water repellent. They are polymers of linear structure, i.e. their molecules  
are elongated and are thread like. This, type of structure is fusible, soluble, highly  
plastic, capable of forming thin flexible threads and films. Examples are Polytetra  
Flouroethylene (P.T.F.E. or Teflon), Polyvinyl Chloride (P.V.C.).  
Thermosetting Plastic Materials:  
They undergo great changes when subjected to high temperatures for quite  
sometimes. They are said to be baked and no longer can melt or be dissolved. They are  
less elastic, more brittle and lose their elasticity when subjected to prolonged heating.  
So they cannot be remoulded in different shapes once they are set and hardened.  
They are used, when an insulation is to withstand high temperatures without melting  
or losing its shape and mechanical strength. Thermosetting plastic substances are  
space-polymers and the molecules branch off in various directions during  
polymerisation.  
Examples of the natural insulating materials are cotton, rubber, wood, mica.  
Rubber  
cotton  
wood  
3
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
E. Magnetic Materials  
Soft magnetic materials:  
They have small enclosed area of hysteresis loop, high permeability, high  
saturation value, low eddy current losses which are achieved by using laminated  
cores, less residual magnetism. Soft magnetic materials retain their magnetism as long as  
they are energised by an external magnetic field; Example: Alpha iron, super  
permalloy (Ni-Fe-Mo), silicon ferrite. Soft magnetic materials are used for the  
construction of cores for electrical machines, transformers, electromagnets reactors and  
cores of audio frequency couplings and matching transformers in telecommunication.  
Hard Magnetic materials:  
They have a gradually rising magnetization curve with large hysteresis loop area and  
hence large energy losses. They have high value of retentivity and high value of coercivity  
and low permeability. To saturate the hard magnetic materials, a high magnetizing  
force is required. Hard magnetic materials have the property of retaining their magnetism  
even after the magnetising field is removed. Example: Alnico (Al-Ni-Co), Cobalt DE04  
steel and retaining the same for a long time. Due to this property they are used in  
the manufacture of permanent magnets.  
F. Special Materials  
Each of the special materials described below has a definite game effect. Some  
creatures have damage reduction based on their creature type or core concept. Some are  
resistant to all but a special type of damage, such as that dealt by evil-aligned weapons or  
bludgeoning weapons. Others are vulnerable to weapons of a particular material. Characters  
may choose to carry several different types of weapons, depending upon the campaign and  
types of creatures they most commonly encounter.  
Adamantine: This ultrahard metal adds to the quality of a weapon or suit of armor.  
4
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Unit 2: ELECTRIC EQUIPMENT  
Heat pump  
Lightning arrester  
Sockets and switch  
Magnetic starter  
Microwave oven  
Circuit breaker  
Electrical system  
Oxygen generator  
controller  
Overload protector  
Actuator  
Thermal relay  
Auto- starter  
Automatic vacuum pump  
Dispenser  
Amplifier  
Fuse  
Electric cable  
Electric pipeline  
Relay  
Ceiling roses  
Synchronous machine  
Alarm bell  
Surge arrester  
Lightning arrester  
5
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Three phase circuit breaker  
Step- down transformer  
Stepless transformer  
Universal electricmeter  
Cable ladder  
Magnetic contactor  
Voltage regulator  
Underground cable  
Power capacitor  
PLC programmer  
Cable tray  
Force sensor  
Frequency converter Bolt, nut and washes  
Hand drill  
Insulated pliers  
Hydraulic pump  
Spanner  
Adjustable wrench  
Screwdriver  
Synchronous generator  
Magnetic brake  
clutch  
Gear box  
Gear motor  
6
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Medium voltage fuses  
Busbar  
Central control box  
Ceramic insulator  
Disconnect switch  
Band conveyor  
Electric fan  
Electric iron  
Electric cooker  
Pressure cooker  
Light bulb  
Flourescent tube  
Oil- immersed transformer  
Resistor  
Rheostat  
Varistor  
Dry- type transformer Current transformer  
Ammeter  
Voltmeter  
Wattmeter  
7
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Unit 3: TEST AND REPAIR INSTRUMENT  
1. General Safety Considerations  
It is SLAC policy to comply with Occupational Safety and Health Administration  
(OSHA) regulations, the National Electrical Code (NEC), and other established safety  
standards to reduce or eliminate the dangers associated with the use of electrical energy.  
Every person on the SLAC site is exposed to electricity to some extent. The SLAC electrical  
safety program provides the SLAC community with the minimum knowledge of safety and  
recommended practices necessary to protect against electrical shock or burns. The electrical  
safety program also provides hazard awareness information to those who use electrical  
equipment.  
All electrical wiring and equipment must comply with NEC, OSHA regulations, and  
numerous other established safety and engineering standards. This chapter should not be  
construed as a synopsis of all electrical requirements or as a substitute for formal study,  
training, and experience in electrical design, construction, and maintenance.  
2. Some electronic equipment used to test and repair  
Digital voltmeter checking a prototype  
The following items are used for basic  
measurement of voltages, currents, and components  
in the circuit under test.  
Ammeter, e.g. Galvanometer or Milliameter  
e.g.,  
VOM  
(Volt-Ohm-  
Milliameter) or DMM (Digital Multimeter)  
(Measures all of the above)  
The following are used for stimulus of the circuit under test:  
The following analyze the response of the circuit under test:  
Oscilloscope (Displays voltage as it changes over time)  
And connecting it all together:  
8
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Advanced or less commonly used equipment  
Meters  
A multimeter with a built in clamp facility.  
Pushing the large button at the bottom  
opens the lower jaw of the clamp, allowing  
the clamp to be placed around a conductor  
(wire).  
Howard piA digital multimeter  
Solenoid voltmeter (Wiggy)  
Clamp meter (current transducer)  
Wheatstone bridge (Precisely measures resistance)  
Capacitance meter (Measures capacitance)  
LCR meter (Measures inductance, capacitance, resistance and combinations thereof)  
EMF Meter (Measures Electric and Magnetic Fields)  
Electrometer (Measures charge)  
Probes  
RF probe  
Signal tracer  
Analyzers  
Logic analyzer (Tests digital circuits)  
Spectrum analyzer (SA) (Measures spectral energy of signals)  
Protocol analyzer (Tests functionality, performance and conformance of protocols)  
Vector signal analyzer (VSA) (Like the SA but it can also perform many more useful  
digital demodulation functions)  
Time-domain reflectometer (Tests integrity of long cables)  
Semiconductor curve tracer  
Signal-generating devices  
Signal generator  
Frequency synthesiser  
Function generator  
Digital pattern generator  
Pulse generator  
Signal injector  
Leader Instruments LSG-15 signal  
generator  
9
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Miscellaneous devices  
Continuity tester  
Cable tester  
Test light  
Transistor tester  
Tube tester  
Hipot tester  
Network  
characterize  
complete computer networks)  
3. Some kinds of test  
analyzer (used to  
Electrical tester pen  
Receptacle tester  
components or  
Electrical testing can be taken in situations (mostly low voltage, ie not exceeding 1000  
V ac or 1500 V dc) where equipment like domestic appliances is being tested. Most of this  
equipment will be used on mains supply voltages of 230 V ac single phase and 400 V ac  
three phase.  
Check and Inspection of some specific equipment:  
Check and Inspection  
Item  
Acceptance  
Criteria  
No  
Steps  
1.1 2.2KV 1. Basic  
Switch Inspection  
- Fill out the check list  
IFC DWG  
Gear  
2. Insulation  
- 6000V Megger for main circuit 200m  
( with circuit breaker )  
Resistance Test  
- 500V Megger for control circuit  
5m  
( phase to earth with remain  
phase)  
3. High Voltage  
Test  
DC 38KV for 1 min-phase to  
earth with remain phases  
- To be carried out on SWGR  
busbar connection and earth  
system joints. And bolt torque to  
be as per V/D requirement  
- All features switchboard  
function as intended to be  
demonstrated by power  
to withstand  
4. Conductivity  
Test  
less than  
200%  
5. Function Test  
6. Relay Test  
IFC DWG  
All protection relay be tested at  
the normal setting to verify their  
operation parameters, with  
secondary injection.  
approved  
relay setting  
and curves  
10  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
- Protection Relay Check  
- Stap setting as per Samsung  
Setting Record  
- Tripping time setting as per  
Samsung Setting Record  
- Traveling Time at selected  
T/D tap  
- Verify the operation of the  
switching devices tripping  
mechnism and all alams and  
intertrips.  
7. Phase Rotation - Disconnect 22KV cable and  
Clock Wire  
Test  
apply 400V 3  
+ Phase temp: power, and check  
phases  
- Rotation All terminals  
to be carried out on diff . Relay  
CTs before Function Test  
8. CT Polarity  
Check  
same as V/D  
drawing  
2.1 22KV  
cable  
1. Basic  
- Fill out the check list  
IFC DWG  
Inspection  
2.2 22KV  
cable  
2. Insulation  
Resistance Test  
and Continuiry  
- 5000V Megger for phase to  
earth with remain phases  
200M  
DC 30.4KV for 1 min-phase to  
earth with remain phases (cable to  
be disconnected )  
3. High Voltage  
Test  
to withstand  
3.1 22/6.6 1. Basic  
KV  
Inspection  
- Fill out the check list  
IFC DWG  
75 M  
TR  
2.Insulation  
Resistance Test  
5000V Megger for primary  
( oil  
Immer  
sed )  
2500V Megger for secondary  
1. Times Measurement  
Fill out the check list  
75M  
3.Oil Test  
30KV/2.5mm  
IFC DWG  
4. Function Test  
4.1 22kv/4 1. Basic  
00V  
TR (  
oil  
Inspection  
Fill out the check list  
IFC DWG  
75 M  
2.Insulation  
Resistance Test  
3.Oil Test  
5000V Megger for primary  
500V Megger for secondary  
1. Times Measurement  
Fill out the check list  
75 M  
Immer  
sed  
30KV/2.5mm  
IFC DWG  
IFC DWG  
4. Function Test  
5.1 6.6KV. 1. Basic  
Fill out the check list  
11  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
SWGR Inspection  
2.Insulation  
2500V Megger for main circuit (  
Resistance Test  
with circuit breaker )  
500V Megger for control circuit (  
phase to earth with remain  
phases)  
200M  
5M  
3. High Voltage DC 16.5KV for 1 min- phase to to withstand  
Test  
Earth with remain phases (  
voltage transformer and load to be  
disconnected)  
4. Conductivity to be carried out on SWGR less than 20%  
Test  
busbar  
Connection and earth  
system joint. And bolt Torque to  
be as per V/D requirement.  
All features of switchboard  
function as Intended to be  
demonstrated by temp power  
All protection relays shall be  
tested at the normal setting to  
verify their operation parameters,  
with secondary  
5.Function Test  
6.Relay Test  
IFC DWG  
injection.  
1- Protection Relay Check  
- Stap setting as per Samsung  
Setting Record  
- Tripping Time Setting as per  
samsung Setting Record  
- Travelling time at selected  
T/D and Tap  
- Verify the operation of the  
switching devices tripping  
mechnism and all alarms and  
intertrips  
7. Phase Rotation Disconnect 22Kv cable and  
clock wise  
Test  
apply 400V 3Phase temp: power,  
and check phases  
Rotation All Terminals  
8. CT Polarity to be carried out on diff . Relay  
Check CTs before Function Test  
12  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Unit 4: SAFETY IN INDUSTRIAL ELECTRICAL APPLICATION  
1. The cause and effect of accident in electric field  
Electrical injuries can be caused by a wide range of voltages but the risk of injury is  
generally greater with higher voltages and is dependent upon individual circumstances. Torch  
batteries can ignite flammable substances.  
Alternating current (AC) and Direct Current (DC) electrical supplies can cause a range of  
injuries including:  
Electrical burns  
Electric shock  
A voltage as low as 50 volts applied  
between two parts of the human body  
causes a current to flow that can block the  
electrical signals between the brain and  
the muscles. This may have a number of  
effects including:  
Stopping the heart beating properly  
Preventing the person from breathing  
Causing muscle spasms  
13  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
The exact effect is dependent upon a large number of things including the size of the voltage,  
which parts of the body are involved, how damp the person is, and the length of time the  
current flows.  
Electric shocks from static electricity such as those experienced when getting out of a car or  
walking across a man-made carpet can be at more than 10,000 volts, but the current flows for  
such a short time that there is no dangerous effect on a person. However, static electricity can  
cause a fire or explosion where there is an explosive atmosphere (such as in a paint spray  
booth).  
Electrical burns  
When an electrical current passes through the  
human body it heats the tissue along the length of  
the current flow. This can result in deep burns that  
often require major surgery and are permanently  
disabling. Burns are more common with higher  
voltages but may occur from domestic electricity  
supplies if the current flows for more than a few  
fractions of a second.  
Thermal burns  
Overloaded, faulty, incorrectly maintained, or  
shorted electrical equipment can get very hot,  
and some electrical equipment gets hot in normal  
operation. Even low voltage batteries (such as  
those in motor vehicles) can get hot and may  
explode if they are shorted out.  
People can receive thermal burns if they get too near hot surfaces or if they are near an  
electrical explosion. Other injuries may result if the person pulls quickly away from hot  
surfaces whilst working at height or if they then accidentally touch nearby machinery.  
A single low voltage torch battery can generate a spark powerful enough to cause a fire or  
explosion in an explosive atmosphere such as in a paint spray booth, near fuel tanks, in  
sumps, or many places where aerosols, vapours, mists, gases, or dusts exist.  
a. Safety equipments  
Personal protective equipment (PPE)  
Personal protective equipment (PPE) is clothing, equipment or substances designed to  
be worn by someone to protect them from risks of injury or illness.  
PPE should only be considered as a control measure when exposure to a risk cannot be  
minimised in another way, or when used in conjunction with other control measures as a  
final barrier between the worker and the hazard. PPE does not control the hazard at the  
source. PPE can include:  
14  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Ey  
Hearing protective  
devices, such as ear  
muffs and ear plugs  
e and face protection, such as goggles  
Respirators  
Safety helmets and sun  
hats  
Safety boots  
Gloves  
High visibility vest  
Life jackets  
2. The methods of advoiding accidents  
→ Equipment must be locked  
out and tagged out before  
preventive maintenance or  
servicing is performed.  
15  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
A variety of possible solutions may be implemented  
to reduce or eliminate the risk of injury associated  
with electrical work. Examples of solutions include  
the use of insulation, guarding, grounding, electrical  
protective devices, and safe work practices.  
→
Lockout devices are  
available in various shapes  
and sizes that allow for the  
lockout of standard control  
devices.  
→ Lockout/tagout kits comply  
with OSHA lockout/tagout  
standards.  
→ Clothing should fit snugly  
to avoid danger of becoming  
entangled  
in  
moving  
machinery or creating a  
tripping or stumbling hazard.  
16  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
→ Always use the correct fire  
Extinguisher for the class of  
fire.  
17  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
The use of electrical equipment can create serious health and safety risks in the hairdressing,  
nail and beauty industry, particularly in wet conditions. Damage to equipment increases this  
risk. Electrical shock can result in electrocution, burns and injuries from falls.  
Extension leads and flexible cables must be protected from damage, including from liquid.  
Electrical equipment must be either:  
inspected, tested and tagged or  
connected to a residual current device (RCD).  
Inspecting, testing and tagging by a competent person  
A competent person must inspect, test and attach  
a durable tag to the equipment every 12 months.  
If the equipment is safe to use, the tag must show  
the date by which the equipment must be  
inspected and tested again;  
If the equipment is not safe to use, the tag must  
warn people not to use the equipment.  
The equipment must also be immediately  
withdrawn from use.  
Residual current device (RCD)  
If the equipment is to be connected to an RCD,  
(known as a safety switch), the device may be  
either portable, or installed at the switchboard.  
An RCD must be tested immediately after  
connection and at least every 3 months.  
A competent person must also test the device  
at least every 2 years.  
If a portable RCD is not working properly, it  
must be tagged to warn people not to use the  
device and immediately withdrawn from use.  
18  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Employ a competent person  
You are encouraged to employ an  
electrician to perform these tasks to ensure  
electrical equipment is safely maintained.  
The advantage of using an electrician is  
that if the equipment is faulty, the  
electrician is licensed to repair it.  
Control measures  
Substitution  
Use splash proof or waterproof electrical equipment instead of standard equipment if  
work must be carried out in wet conditions.  
Use power boards instead of double adaptors.  
waterproof electrical equipment  
power boards  
Redesign  
Install additional socket outlets to avoid overloading power outlets.  
Administrative controls  
Make sure workers are trained in the use of equipment and that manufacturer’s  
instructions are followed.  
Store and operate equipment away from damp areas when not in use.  
Make sure leads do not run across wet surfaces or any place where they may be easily  
damaged.  
Run leads along the edges of corridors to minimise the possibility of trips and falls.  
Keep leads away from heat, oil and chemicals to prevent insulation damage.  
Clean up liquid spills as soon as possible.  
19  
TIẾNG ANH CHUYÊN NGÀNH ĐIỆN CÔNG NGHIỆP  
Conduct regular (monthly intervals or more frequently if necessary) visual inspections  
of equipment to check that the equipment (including accessories, connecting lead and  
plug) has no obvious external damage or inadequate temporary repairs.  
Make a list containing the description, make and serial number of all equipment and  
the date when tested to assist you in ensuring all electrical items are tested.  
When adjusting or cleaning equipment, SWITCH OFF the power and pull out the plug  
¿ NOT by the cord.  
Do not touch equipment with wet hands or use a wet cloth to clean sockets.  
Make sure flexible cords are fully unwound and kept clear of work traffic.  
Do not run too many pieces of equipment from one socket.  
20  